INVARAS™ 100 | OEM NDIR CO₂ GAS ANALYZER
Proven Performance
< ±1%
Accuracy of
calibrated measurement
range*
< 0.25 ppm
RMS noise at
500 ppm**
< 0.4 ppm/hr
Total CO2 drift
at 500 ppm
< 4.5
sec
T90 from 0 to 500 ppm
at 400 cc/min
* Accuracy is limited by the accuracy of the calibration mixture. **With 1.6-second filtering.
Once the analyzer is inside your system,
its performance becomes part of yours.
INVARAS™ 100 is an OEM NDIR CO₂ gas analyzer designed for integration into scientific instruments, monitoring equipment, and automated systems.
Day-one accuracy is only the beginning.
When CO₂ measurement becomes part of a larger system, measurement stability, communication, and service requirements all influence the performance of the equipment.
INVARAS 100 is engineered for these realities.
A true measured-zero reference, advanced thermal regulation, and integration-ready communications work together to support accurate, repeatable CO₂ measurement throughout continuous operation and long-term deployment.
The result is measurement confidence you can build into your system.
Confidence starts with the measurement
Start from
a known
zero.

TRUEZERO™ TECHNOLOGY
Every confident measurement begins with a trusted reference.
TrueZero™ Technology periodically establishes a measured CO₂-free zero reference, providing a known baseline for subsequent measurements.
By correcting for changes that can affect the analyzer’s measurement baseline over time, TrueZero supports highly accurate CO₂ measurement and long-term measurement confidence.
Keep drift
out of
the data.

DRIFT-FREE PERFORMANCE
Analyzer drift can introduce uncertainty into measurements without immediately revealing itself.
INVARAS 100 is engineered to minimize the effects of drift during continuous operation, helping maintain measurement integrity over time.
With a total CO₂ drift specification of <0.4 ppm/hr at 500 ppm, INVARAS 100 is designed for applications where stable data matters.
Changing conditions shouldn’t change the measurement.

ENHANCED MEASUREMENT STABILITY
Real systems operate under changing environmental conditions.
Advanced thermal regulation maintains a stable internal measurement environment as ambient conditions change.
This supports accurate, repeatable, low-noise CO₂ measurement throughout continuous operation.
OEM CO₂ MEASUREMENT
Built to integrate.
Not complicate.
Every OEM system has its own measurement, communication, and operating requirements.
INVARAS 100 combines compact hardware with configurable reporting and analog and digital interfaces, providing practical options for incorporating CO₂ measurement into the host system.


Compact PCB Format
Designed for embedded OEM applications, INVARAS 100 provides a compact measurement platform for integration into larger equipment.

Fixed-length Data Output
Predictable data-string formatting supports consistent communication and simplifies data handling within the host system.

Configurable Reporting
Configure measurement reporting to focus on the variables and operating information relevant to your application.

Analog & Digital Interfaces
RS-232, USB, voltage, and current outputs provide communication options for integration into compatible monitoring and control systems.
NO FACTORY RECALIBRATION REQUIRED

Keep it deployed.
Once an analyzer is embedded inside an OEM system, removing it for factory recalibration can interrupt operation and create additional service requirements.
INVARAS 100 eliminates the need for factory recalibration, allowing the analyzer to remain inside the system throughout long-term deployment.
User-programmable calibration remains available when an application requires it.
Appropriate calibration verification, sample handling, and system maintenance should still be performed according to application requirements.
Long-term measurement confidence without routine factory returns.
GAS ANALYSIS SOFTWARE

See what your analyzer sees.

INVARAS 100 is supported by PP Systems GAS Software, providing engineers with direct visibility into analyzer operation during setup, testing, and evaluation.
GAS Software allows users to:
- Monitor live CO₂ measurement data.
- Configure analyzer settings.
- Log environmental sensor data when configured.
- Review analyzer performance.
- Confirm operation before deployment.
From initial setup through system testing, GAS Software helps engineers evaluate the analyzer and its measurement data.
WHERE INVARAS 100 FITS
Built around your application.
INVARAS 100 is designed for manufacturers, system integrators, and researchers developing equipment that requires accurate, stable CO₂ measurement.
Controlled
Environments

CO₂ measurement within equipment designed to maintain controlled atmospheric conditions.
Growth Chambers
& Incubators

Integrated CO₂ measurement for equipment used in plant growth, incubation, and controlled-environment research.
Environmental
Monitoring

CO₂ measurement within environmental monitoring instruments and research systems.
Industrial & Process
Monitoring

Integration into compatible process-monitoring equipment requiring continuous CO₂ concentration measurement.
Laboratory & Research
Instrumentation

A compact CO₂ measurement platform for custom scientific instruments and laboratory systems.
Carbon & Bioprocess Monitoring

Potential integration into compatible carbon-monitoring, fermentation, and bioprocess equipment, subject to application-specific evaluation.
Application suitability depends on measurement range, gas composition, environmental conditions, sample conditioning, and integration requirements.
Designed for your system. Let’s talk about requirements.
Selecting the right CO₂ analyzer starts with understanding the application.
The Right
Measurement Range
Choose a calibrated CO₂ measurement range appropriate for the expected concentrations and measurement requirements.
The Right
Operating Conditions
Consider gas composition, humidity, pressure, temperature, sample flow, and gas conditioning requirements.
The Right
Integration
Evaluate the host system’s communications, data outputs, available power, and installation requirements.
Every application is different. We’re here to help you evaluate yours.
Technical Specifications
| Parameter | Specification/Conditions |
| Method | Non-dispersive infrared (NDIR) absolute absorptiometer; linearized and temperature/pressure corrected. |
| CO₂ Calibrated Ranges | 0–1,000; 0–2,000; 0–5,000; 0–10,000; 0–20,000; 0–30,000 ppm (µmol mol-¹). |
| Accuracy | <±1% of full scale; limited by calibration gas accuracy. |
| RMS Noise | <0.25 ppm at 500 ppm with 1.6-second filtering. |
| Lower Limit of Detection |
<0.25 ppm at 0 ppm; 3σ, default configuration (6-second internal averaging). |
| Total CO₂ Drift |
<0.4 ppm/hr at 500 ppm. |
| T90 |
<4.5 seconds from 0 to 500 ppm at 400 cc/min. |
| Calibration |
User-programmable calibration, if required. No routine factory recalibration required under normal operation. |
| Sampling / Reporting |
10 Hz internal sampling; averaged data output at 1-second intervals by default (configurable). |
| Flow Rate |
100–1,000 cc/min; 200–500 cc/min recommended |
| Operating Temperature |
−20°C to +45°C. |
| Power |
6–18 VDC; approximately 9 W warm-up, 1–3 W normal operation, ambient dependent. |
| PCB Dimensions / Mass |
13.5 × 7.5 × 3.5 cm (L × W × H), 0.2 kg. |
| Optional Enclosure / Mass |
14.5 × 10.5 × 5.5 cm (L × W × H), 0.5 kg. |
| Optional RH Sensor |
Relative humidity sensor (optional): 0–80% RH; <±1.5% RH; non-condensing. |
| Connections |
Gas inlet, exhaust, and zero barbed fittings; USB Mini Type B, 12-pin I/O terminal block and power connections. |
| Digital Interface |
RS-232 and USB; fixed-length output strings and configurable reporting (default 1-second interval). |
| Analog Interface |
Two 0–5 V channels (CO₂ and optional RH-sensor-derived H₂O); 4–20 mA for CO₂. |
| Terminal Block |
12-pin input/output terminal block. |
Accuracy is limited by the accuracy of the calibration mixture.
Specifications are subject to change. Contact PP Systems regarding specific integration requirements and available configurations.
Data You Can Build On.
What are you building?
When CO₂ measurement becomes part of your equipment, its performance becomes part of yours.
Let’s discuss your application and how INVARAS 100 can bring long-term measurement confidence to your next design.
INVARAS™ 100 — CO₂ measurement built for the long run.